V23132-xxx Datasheet PDF - Tyco

www.Datasheet-PDF.com

V23132-xxx
Tyco

Part Number V23132-xxx
Description High Current Relay HCR
Page 5 Pages


V23132-xxx datasheet pdf
Download PDF
V23132-xxx pdf
View PDF for Mobile

No Preview Available !

Special products
High current switches
High current relay HCR
Features
– Switches currents of more
than 300 A
– Heat, moisture and vibration
resistant
– Minimal contact resistance
www.DataSheTeyt4pUic.acloampplications
– Preheating air for diesel
engines
– Preheating catalytic
converters
– Car heating systems
– Electrical power steering
– Electrical pumps
– Primary and/or engine
switches
– Electrical valve control
– Switches for loading ramps
– Electrically adjustable cam
shaft
– Dual battery switches
– Battery disconnection
Powertrain
Systems
Chassis
Systems
Design
Dustproof;
optional: sealed version,
sealing in accordance with
IEC 60 068;
immersion cleanable:
protection class IP67 to IEC
60 529 (EN 60 529)
Weight
Approx. 7.76 oz. (220 g)
Nominal voltage
12 V or 24 V;
other nominal voltages
available on request
Terminals
– Quick connect terminals
(coil)
– Screw terminals (load)
Safety
Security
Body
Driver
Convenience
Information
Conditions
All parametric, environmental
and endurance tests are
performed according to
EIA Standard RS-407-A at
standard test conditions
unless otherwise noted:
23 °C ambient temperature,
20-50% RH, 29.5 ± 1.0" Hg
(998.9 ±33.9 hPa).
Car Industry
Truck
Industry
132_3d01
Other
Industry
204
All specifications subject to change. Consult Tyco Electronics AMP GmbH for latest specifications.



No Preview Available !

Special products
High current switches
High current relay HCR
Dimension drawing
Bridging make/make version
3.307
(84)
2.48
(63)
1.575
(40)
.531
www.DataShee(t143U..5co) m
connector
2-pole
2.795
(71)
Ø .256
(6.5)
.669
(17)
screw terminals M6
1.575
(45) 2.567
(65.2)
ECR1666-X
View on the terminals (bottom view)
.610
(15.5)
ECR1667-6
Changeover version
.531
(13.5)
.276
(7)
.413
(10.5)
Quick connectors
similar to ISO 8092-1
2.185
(55.5)
.177
(4.5)
.079
(2) 2.008
(51)
.669 .669
(17) (17)
.413
(10.5)
screw terminals M6
1.575
(40)
1.575
(45)
2.519
(64)
ECR1452-F
View on the terminals (bottom view)
.394
(10)
.551
(14)
2.48
(63)
.610
(15.5)
ECR1453-N
All specifications subject to change. Consult Tyco Electronics AMP GmbH for latest specifications.
205



No Preview Available !

Contact data
Contact configuration
Contact material
Circuit symbol
(see also Pin assignment)
Special products
High current switches
High current relay HCR
Make contact/
Form A
Bridging make contact/
Form X
AgNi0.151)
Changeover contact/
Form C
Max. switching current2)
On 3)
300 A (1000 A for 10 cycles)
Off
www.DataSheeLti4mUit.icnogmcontinuous current
at 23 °C
at 85 °C
300 A (1000 A for 10 cycles)
150 A4)
130 A4) / 150 A5)
Voltage drop (initial) at 100 A
Typ. 50 mV
Increase in coil temperature at 10 A load
Mechanical endurance (without load)
Typ. 0.3 °C
> 107 operations
Electrical endurance
For resistive load of 150 A, 1 sec make, 1 sec break time,
13.5 V switching voltage, 24 °C
> 3 x 104 operations
1)
2)
Optional: AgSnO2 contact material for higher switching loads (300 A on/off, 13.5 V, 23 °C, > 5 x 104 operations)
The values apply to a resistive load or inductive load with suitable spark suppression.
3) This current may flow for a maximum of 3 sec for a make/break ratio of 1 : 10.
4) Cable 16 mm2
5) Cable 25 mm2
Operating voltage range
300
ECR1449-V
Does not take into account
the temperature rise due to
the contact current
E = pre-energization
Pin assignment
1 make contact/
1 form A
1 bridging make contact/
1 form X
1 changeover contact/
1 form C
13
52
ECR1669-M
1 3 52
ECR1668-E
13
4 52
ECR1455-5
206
All specifications subject to change. Consult Tyco Electronics AMP GmbH for latest specifications.



No Preview Available !

Special products
High current switches
High current relay HCR
Coil data
Available for nominal voltages
Nominal power consumption of the unsuppressed coil at nominal voltage
Test voltage winding/contact
Upper limit temperature for the coil
Maximum ambient temperature range1)
Max. switching rate without contact loading
Operate time (12 VDC)
Release time (12 VDC)
1) See also operating voltage range diagram
N.B.
www.DataSheAetl4oUw.rceosmistive device in parallel to the relay coil slows the armature movement down
and reduces the lifetime caused by increased erosion and/or higher risk of contact tack welding.
12, 24 VDC (other coils on request)
Typ. 3.3 W
1000 VACrms
155 °C
– 40 to + 125 °C
10 Hz
25 msec
8 msec
Mechanical data
Cover retention
pull
push
500 N (112.5 lbs)
500 N (112.5 lbs)
Terminals
Pull force
Push force
Resistance to bending, force applied to front
Resistance to bending, force applied to side
Torsion of screw bolts
150 N (33.75 lbs)
150 N (33.75 lbs)
20 N (4.5 lbs)1)
20 N (4.5 lbs)1)
5 Nm
Enclosures
Dust cover
Protects relay from dust. For use in passenger compartment or enclosures
1) Values apply 2 mm from the end of the terminal. When the force is removed, the terminal must not have moved by more than 0.3 mm.
Operating conditions
Temperature range, storage
Test
Dry heat
Temperature cycling
Damp heat
constant
Industrial atmosphere
Vibration resistance
Shock resistance
Load dump
Jump start
Flammability
Relevant standard
IEC 60 068-2-2
IEC 60 068-2-14
Testing as per
Ba
Nb
-40 °C to 155 °C
Dimension
500 h
10 cycles
IEC 60 068-2-3
Ca
IEC 60 068-2-60
method 4
IEC 60 068-2-6
IEC 60 068-2-27 (half-sine pulse form)
acceleration, acc. to position
ISO 7637
DIN 40 839 Part 1
5 sec 16 V
10 sec 16 V
25 sec 25 V
UL94-HB
500 h
21 days
10 … 200 Hz
10 g
6 msec
20 g
3 cycles
Comments
100 °C
– 40/+ 85 °C (5 °C per min.)
40 °C, 93% RH
25 °C
No change in the
switching state > 10 µsec
No change in the
switching state > 10 µsec
All specifications subject to change. Consult Tyco Electronics AMP GmbH for latest specifications.
207



V23132-xxx datasheet pdf
Download PDF
V23132-xxx pdf
View PDF for Mobile


Related : Start with V23132-xx Part Numbers by
V23132-xxx High Current Relay HCR V23132-xxx
Tyco
V23132-xxx pdf

Index :   0   1   2   3   4   5   6   7   8   9   A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z   

This is a individually operated, non profit site. If this site is good enough to show, please introduce this site to others.
Since 2010   ::   HOME   ::   Contact