S-19106
Seiko

Part Number S-19106
Description OPERATION BUILT-IN DELAY CIRCUIT VOLTAGE DETECTOR
Page 39 Pages


S-19106 datasheet pdf
Download PDF for PC
S-19106 pdf
View PDF for Mobile


No Preview Available !

S-19104/19106 Series
www.sii-ic.com
© Seiko Instruments Inc., 2014
FOR AUTOMOTIVE 105°C OPERATION BUILT-IN DELAY CIRCUIT (EXTERNAL DELAY TIME SETTING)
VOLTAGE DETECTOR WITH SENSE PIN
Rev.1.0_00
The S-19104/19106 Series is a high-accuracy voltage detector developed using CMOS technology. The detection voltage
is fixed internally with an accuracy of ±3.5% (VDET(S) 2.2 V). It operates with current consumption of 500 nA typ.
Apart from the power supply pin, the detection voltage input pin (SENSE pin) is also prepared, so the output is stable even
if the SENSE pin falls to 0 V.
The release signal can be delayed by setting a capacitor externally, and the release delay time accuracy is ±34% (CD =
4.7 nF, Ta = 40°C to +105°C).
Two output forms Nch open-drain output and CMOS output are available.
Caution This product can be used in vehicle equipment and in-vehicle equipment. Before using the product in
the purpose, contact to SII is indispensable.
Features
Detection voltage:
1.2 V to 5.0 V (0.1 V step)
Detection voltage accuracy:
±3.5% (2.2 V ≤ −VDET(S) 5.0 V, Ta = 40°C to +105°C)
±(2.5% + 22 mV) (1.2 V ≤ −VDET(S) < 2.2 V, Ta = 40°C to +105°C)
Current consumption:
500 nA typ.
Operation voltage range:
0.95 V to 10.0 V
Hysteresis width:
5% ± 2% (Ta = 40°C to +105°C)
Release delay time accuracy: ±34% (CD = 4.7 nF, Ta = 40°C to +105°C)
Output form:
Nch open-drain output (Active "L")
CMOS output (Active "L")
Operation temperature range: Ta = 40°C to +105°C
Lead-free (Sn 100%), halogen-free
AEC-Q100 in process*1
*1. Contact our sales office for details.
Applications
For automotive use (accessory, car navigation system, car audio system, etc.)
Package
SOT-23-5
Seiko Instruments Inc.
1

S-19106 datasheet pdf
Download PDF for PC
S-19106 pdf
View PDF for Mobile


Related : Start with S-1910 Part Numbers by
S-19104 OPERATION BUILT-IN DELAY CIRCUIT VOLTAGE DETECTOR S-19104
Seiko
S-19104 pdf
S-19106 OPERATION BUILT-IN DELAY CIRCUIT VOLTAGE DETECTOR S-19106
Seiko
S-19106 pdf

Index :   0   1   2   3   4   5   6   7   8   9   A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z   NEW   

Since 2010   ::   HOME   ::   Contact