R0605300L Datasheet PDF - PDI

www.Datasheet-PDF.com

R0605300L
PDI

Part Number R0605300L
Description Si Reverse Hybrid
Page 4 Pages


R0605300L datasheet pdf
Download PDF
R0605300L pdf
View PDF for Mobile

No Preview Available !

www.DataSheet4U.com
Product Specification
R0605300L
Si Reverse, low current, 5 – 65MHz, 30.5dB typ. Gain @ 65MHz, 135mA max. @ 24VDC
FEATURES
Excellent linearity
Superior return loss performance
Extremely low distortion
Optimal reliability
Low noise
Unconditionally stable under all terminations
APPLICATION
5 to 65 MHz CATV amplifier
for reverse channel systems
DESCRIPTION
Hybrid reverse amplifier employing silicon dice
LIMITING VALUES
In accordance with the Absolute Maximum Rating System (IEC 60134)
SYMBOL
Vi
Vov
Tstg
Tmb
PARAMETER
RF input voltage (single tone)
DC supply over-voltage (5 minutes)
storage temperature
operating mounting base temperature
R0605300L
Si Reverse Hybrid , low current
5 – 65 MHz
30.5dB typ. Gain @ 65 MHz
135mA max. @ 24VDC
MIN.
-
-
- 40
- 30
MAX.
65
30
+ 100
+ 100
UNIT
dBmV
V
°C
°C
CHARACTERISTICS
Table 1: S-Parameter, Noise Figure, DC Current; VB = 24V; Tmb = 30°C; ZS = ZL = 75
SYMBOL PARAMETER
Gp power gain
SL slope 1)
FL flatness of frequency
response
S11 input return loss
S22 output return loss
F noise figure
Itot total current
consumption (DC)
CONDITIONS
f = 5 MHz
f = 65 MHz
f = 5 to 65 MHz
f = 5 to 65 MHz
MIN.
30.0
29.8
-0.2
-
TYP.
30.4
30.5
0.1
MAX.
30.8
-
0.4
± 0.3
UNIT
dB
dB
dB
dB
f = 5 to 65 MHz
f = 5 to 65 MHz
f = 65 MHz
20.0
20.0
-
130.0
2.3
133.0
-
-
3.0
140.0
dB
dB
dB
mA
Notes:
1) The slope is defined as the difference between the gain at the start frequency and the gain at the stop frequency.
Page 1 of 4
2004 Jun 01
Document Revision Level C



No Preview Available !

Product Specification
R0605300L
Si Reverse, low current, 5 – 65MHz, 30.5dB typ. Gain @ 65MHz, 135mA max. @ 24VDC
CHARACTERISTICS
Table 2: Distortion data 5 – 65 MHz; VB = 24V; Tmb = 30°C; ZS = ZL = 75
SYMBOL
CTB
XMOD
CSO
d2
STB
PARAMETER
composite triple beat
cross modulation
composite second order
distortion
second order distortion
third order distortion
CONDITION
7 ch. flat; Vo = 50 dBmV 1)
7 ch. flat; Vo = 50 dBmV 1)
7 ch. flat; Vo = 50 dBmV 1)
MIN.
-
-
-
TYP.
MAX.
- 64
- 55
- 68
UNIT
dBc
dB
dBc
2) - 70 dBc
3) - 66 dBc
Notes:
1)
2)
3)
7 channels, NTSC frequency raster: T7 – T13 (7.0 to 43.0 MHz), +50 dBmV flat output level.
f1 = 83.25 MHz; V1 = 50 dBmV; f2 = 109.25 MHz; V2 = 50 dBmV; fTEST = f1 + f2 = 192.5 MHz.
f1 = 13 MHz; V1 = 50 dBmV; f2 = 25 MHz; V2 = V1; f3 = 7 MHz; V3 = V1;
fTEST = f1 + f2 - f3 = 31 MHz.
Composite Second Order (CSO)
The CSO parameter (both sum and difference products) is defined by the NCTA.
Composite Triple Beat (CTB)
The CTB parameter is defined by the NCTA.
Cross Modulation (XMOD)
Cross modulation (XMOD) is measured at baseband (selective voltmeter method), referenced to 100% modulation of the
carrier being tested.
Page 2 of 4
2004 Jun 01
Document Revision Level C



No Preview Available !

Product Specification
R0605300L
Si Reverse, low current, 5 – 65MHz, 30.5dB typ. Gain @ 65MHz, 135mA max. @ 24VDC
I
U
123 5 789
J
øG
S
T
P
C
E
K
N
M
R
O
Q
D
H
B
L
F
A
0 5 10mm
scale
Pinning:
1 2 34567 8 9
Notes:
European
Projection
All Dimensions in mm:
nominal
A 44,6 ± 0,2
B 13,6 ± 0,2
C 20,4 ± 0,5
D 8 ± 0,15
E 12,6 ± 0,15
F 38,1 ± 0,2
G 4 +0,2 / -0,05
H 4 ± 0,2
I 25,4 ± 0,2
J UNC 6-32
K 4,2 ± 0,2
L 27,2 ± 0,2
M 11,6 ± 0,5
N 5,8 ± 0,4
O 0,25 ± 0,02
P 0,45 ± 0,03
Q 2,54 ± 0,3
R 2,54 ± 0,5
S 2,54 ± 0,25
T 5,08 ± 0,25
U 5,08 ± 0,25
min
44,4
13,4
19,9
7,85
12,45
37,9
3,95
3,8
25,2
-
4,0
27,0
11,1
5,4
0,23
0,42
2,24
2,04
2,29
4,83
4,83
max
44,8
13,8
20,9
8,15
12,75
38,3
4,2
4,2
25,6
-
4,4
27,4
12,1
6,2
0,27
0,48
2,84
3,04
2,79
5,33
5,33
Page 3 of 4
2004 Jun 01
Document Revision Level C



No Preview Available !

Product Specification
R0605300L
Si Reverse, low current, 5 – 65MHz, 30.5dB typ. Gain @ 65MHz, 135mA max. @ 24VDC
DEFINITIONS
Data Sheet Status
Objective Product
Specification
Preliminary Product
Specification
Product Specification
This data sheet contains target or goal specifications for product
development.
This data sheet contains preliminary data; supplementary data may
be published later.
This data sheet contains final product specifications.
Limiting values
Limiting values given are in accordance with the Absolute Maximum Rating System (IEC 60134).
Stress above one or more of the limiting values may cause permanent damage to the device.
These are stress ratings only and operation of the device at these or at any other conditions
above those given in the Characteristics sections of the specification is not implied. Exposure to
limiting values for extended periods may affect device reliability.
Application information
Where application information is given, it is advisory and does not form part of the specification.
Premier Devices reserves the right to make changes without further notice to any products herein.
Premier Devices makes no warranty representation or guarantee regarding the suitability of its products for any particular
purpose, nor does Premier Devices assume any liability arising out of the application or use of any product or circuit, and
specifically disclaims any and all liability, including without limitation consequential or incidental damages. “Typical”
parameters which may be provided in Premier Devices datasheets and/or specifications can and do vary in different
applications and actual performance may vary over time. All operating parameters, including “Typicals” must be validated
for each customer application by customer´s technical experts. Premier Devices does not convey any license under its
patent rights nor the rights of others. Premier Devices products are not designed, intended, or authorized for use as
components in systems intended for surgical implant into the body, or other applications intended to support or sustain life,
or for any other application in which the failure of the Premier Devices product could create a situation where personal
injury or death may occur. Should Buyer purchase or use Premier Devices products for any such unintended or
unauthorized application, Buyer shall indemnify and hold Premier Devices and its officers, employees, subsidiaries,
affiliates, and distributors harmless against all claims, costs, damages, and expenses, and reasonable attorney fees
arising out of, directly or indirectly, and claim of personal injury or death associated with such unintended or unauthorized
use, even if such claim alleges that Premier Devices was negligent regarding the design or manufacture of the part.
© Premier Devices Germany GmbH 2004
How to contact us:
Premier Devices Germany GmbH
Loeffelholzstrasse 20, D-90441 Nuernberg, Germany
Phone: +49 (0) 911 9411 233, FAX: +49 (0) 911 9411 198,
Email: sales.germany@premierdevices.com, Internet: http://www.premierdevices.de/
Page 4 of 4
2004 Jun 01
Document Revision Level C



R0605300L datasheet pdf
Download PDF
R0605300L pdf
View PDF for Mobile


Related : Start with R0605300 Part Numbers by
R0605300L Si Reverse Hybrid R0605300L
PDI
R0605300L pdf
R0605300L1 Si Reverse Hybrid R0605300L1
PDI
R0605300L1 pdf
R0605300L2 Si Reverse Hybrid R0605300L2
PDI
R0605300L2 pdf

Index :   0   1   2   3   4   5   6   7   8   9   A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z   

This is a individually operated, non profit site. If this site is good enough to show, please introduce this site to others.
Since 2010   ::   HOME   ::   Contact