PU SERIES
1W UNREGULATED
FEATURES
SINGLE IN LINE PACKAGE
1W UNREGULATED OUTPUT POWER
100% BURN IN
HIGH EFFICIENCY
INTERNAL SMD TECHNOLOGY
NO HEATSINK REQUIRED
UL 94V-0 PACKAGE MATERIAL
CUSTOM SOLUTIONS AVAILABLE
RoHS COMPLIANT
3 YEARS WARRANTY
OUTPUT SPECIFICATIONS
INPUT SPECIFICATIONS
Voltage Set-point Accuracy
+/-2% max Input Voltage Range
+/-10% max
Temperature Coefficient
+/-0.05%/°C Input Filter
Capacitor Typ
Ripple & Noise(20MHz BW)
Line Regulation1
Load Regulation2
100mVp-p max Input Reflected Ripple Current
50mAp-p max
+/-1.2% max Protection
Fuse Recommended
+/-8% max GENERAL SPECIFICATIONS
Minimum Load
Short Circuit Protection
20% of Full Load Efficiency
Momentary Isolation Voltage3
70%-83%
Single/Dual
1500-3000 VDC min
Twin
In to Out
1000 VDC min
ENVIRONMENTAL SPECIFICATIONS
Isolation Resistance
Isolation Capacitance
Out to Out
500 VDC min
109 ohms min
80pF max
Operating Temperature
Storage Temperature
-40°C to +71°C Switching Frequency
-55°C to +125°C MTBF4
100KHz min
>2,000,000 Hours
Humidity
95% max Weight
2.1g Typ
Cooling
Free-Air Convection Case Material
Non-Conductive Plastic
Case Size
19.6mm*6.1mm*10.2mm
19.6mm*7.1mm*10.2mm
Conducted Emissions
EN55022 Class A
Radiated Emissions
EN55022 Class A
ALL SPECIFICATIONS TYPICAL AT NOMINAL LINE, FULL LOAD AND 25 OC UNLESS OTHERWISE NOTED.
1 Line Regulation is for a 1.0% change in input Voltage.
2 Load Regulation is for output load current change from 20% to 100%.
3 1500VDC for 10 seconds,3000VDC for 3 seconds.
4 MIL-HDBK-217F @25 °C , Ground Benign.
DANUBE
http://www.danube.com.tw
5-1
2011/05/03



No Preview Available !

SELECTION GUIDE(1)
1W 1500VDC ISOLATION
MODEL
NUMBER
INPUT OUTPUT OUTPUT
INPUT5
VOLTAGE VOLTAGE CURRENT CURRENT(mA) EFF ISOLATION
(VDC) (VDC)
(mA) FULL NO (%)6
(VDC)
PACKAGE
LOAD LOAD
PUS-0503.3(A or B)
PUS-0505(A or B or E)
PUS-0509(A or B or E)
PUS-0512(A or B or E)
PUS-0515(A or B or E)
PUD-0505(A or B)
PUD-0509(A or B)
PUD-0512(A or B)
PUD-0515(A or B)
PUS-0909(A or B)
PUS-1203.3(A or B)
PUS-1205(A or B or E)
PUS-1209(A or B or E)
PUS-1212(A or B or E)
PUS-1215(A or B or E)
PUD-1205(A or B)
PUD-1212(A or B)
PUD-1215(A or B)
PUS-2403.3C
PUS-2405C
PUS-2409C
PUS-2412C
PUS-2415C
PUS-2424C
PUD-2405C
PUD-2412C
PUD-2415C
5
5
5
5
5
5
5
5
5
9
12
12
12
12
12
12
12
12
24
24
24
24
24
24
24
24
24
3.3
5
9
12
15
+/-5
+/-9
+/-12
+/-15
9
3.3
5
9
12
15
+/-5
+/-12
+/-15
3.3
5
9
12
15
24
+/-5
+/-12
+/-15
300
200
111
84
67
+/-100
+/-56
+/-42
+/-34
111
300
200
111
84
67
+/-100
+/-42
+/-34
300
200
111
84
67
42
+/-100
+/-42
+/-34
274
283
257
253
253
278
260
253
260
148
112
112
107
102
102
112
105
101
57
57
56
54
52
54
57
54
52
35 73
35 71
34 78
33 79
34 79
35 72
34 77
33 79
34 77
24 75
14 74
15 74
14 78
14 82
14 82
15 74
14 79
15 83
9 73
9 73
9 75
9 77
10 80
9 77
10 73
10 77
9 80
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
1500
A or B
A or B or E
A or B or E
A or B or E
A or B or E
A or B
A or B
A or B
A or B
A or B
A or B
A or B or E
A or B or E
A or B or E
A or B or E
A or B
A or B
A or B
C
C
C
C
C
C
C
C
C
Note: Other input to output voltages may be available. Please contact factory.
ORDERING INFORMATION:
FOR EXAMPLE:
PUS-****A(SINGLE OUTPUT A PACKAGE)
PUD-****A(DUAL OUTPUT A PACKAGE)
PUS-****B(SINGLE OUTPUT B PACKAGE)
PUD-****B(DUAL OUTPUT B PACKAGE)
5 NOMINAL INPUT VOLTAGE.
6 NOMINAL INPUT VOLTAGE, FULL LOAD.
DANUBE
http://www.danube.com.tw
5-2
2011/05/03



No Preview Available !

SELECTION GUIDE(2)
1W 1500VDC ISOLATION
MODEL
NUMBER
INPUT OUTPUT OUTPUT
INPUT7
VOLTAGE VOLTAGE CURRENT CURRENT(mA) EFF ISOLATION
(VDC) (VDC)
(mA) FULL NO (%)8
(VDC)
PACKAGE
LOAD LOAD
PUS-0503.3AY
PUS-0505AY
PUS-0509AY
PUS-0512AY
PUS-0515AY
PUD-0505AY
PUD-0512AY
PUD-0515AY
PUS-0909AY
PUS-1203.3AY
PUS-1205AY
PUS-1209AY
PUS-1212AY
PUS-1215AY
PUD-1205AY
PUD-1212AY
PUD-1215AY
PUS-2403.3CY
PUS-2405CY
PUS-2409CY
PUS-2412CY
PUS-2415CY
PUS-2424CY
PUD-2405CY
PUD-2412CY
PUD-2415CY
5 3.3 300 274 34 73 1500
5 5 200 283 34 71 1500
5 9 111 257 35 78 1500
5
12
84
253 34 79
1500
5
15
67
253 35 79
1500
5
+/-5
+/-100 278
35 72
1500
5
+/-12
+/-42 253 33 79
1500
5
+/-15
+/-34 260 34 77
1500
9 9 111 148 24 75 1500
12 3.3 300 112 14 74 1500
12 5 200 112 14 74 1500
12 9 111 107 15 78 1500
12
12
84
102 13 82
1500
12
15
67
102 14 82
1500
12
+/-5
+/-100 112
15 74
1500
12
+/-12
+/-42 105 14 79
1500
12
+/-15
+/-34 101 14 83
1500
24 3.3 300 57 10 73 1500
24 5 200 57 10 73 1500
24
9
111
56
9 75
1500
24 12 84 54 10 77 1500
24 15 67 52 9 80 1500
24 24 42 54 9 77 1500
24
+/-5
+/-100
57
10 73
1500
24
+/-12
+/-42
54
9 77
1500
24
+/-15
+/-34
52
9 80
1500
AY
AY
AY
AY
AY
AY
AY
AY
AY
AY
AY
AY
AY
AY
AY
AY
AY
CY
CY
CY
CY
CY
CY
CY
CY
CY
Note: Other input to output voltages may be available. Please contact factory.
ORDERING INFORMATION:
FOR EXAMPLE:
PUS-****AY(SINGLE OUTPUT AY PACKAGE)
PUD-****AY(DUAL OUTPUT AY PACKAGE)
PUS-****CY(SINGLE OUTPUT CY PACKAGE)
PUD-****CY(DUAL OUTPUT CY PACKAGE)
7 NOMINAL INPUT VOLTAGE.
8 NOMINAL INPUT VOLTAGE, FULL LOAD.
DANUBE
http://www.danube.com.tw
5-3
2011/05/03



No Preview Available !

SELECTION GUIDE(3)
1W DUAL SEPARATE OUTPUT
MODEL
NUMBER
OUTPUT
OUTPUT
INPUT9
INPUT VOLTAGE CURRENT
CURRENT(mA) EFF ISOLATION
VOLTAGE (VDC)
(mA)
PACKAGE
(%)10 (VDC)
(VDC)
FULL NO
OUT1 OUT2 OUT1 OUT2
LOAD LOAD
PUD-050503.3
5
+5 +3.3 +100 +152 286
34 70
1500
F
PUD-050505
5
+5 +5 +100 +100 255
34 78
1500
F
PUD-050509
5
+5 +9 +100 +56 251
33 80
1500
F
PUD-050512
5
+5 +12 +100 +42 250
35 80
1500
F
PUD-050515
5
+5 +15 +100 +34 250
35 80
1500
F
PUD-120505
12
+5 +5 +100 +100 119
15 70
1500
F
PUD-120509
12
+5 +9 +100 +56 104
14 80
1500
F
PUD-120512
12
+5 +12 +100 +42 102
14 82
1500
F
PUD-120515
12
+5 +15 +100 +34 104
14 80
1500
F
PUD-2403.303.3
24
+3.3 +3.3 +152 +152 60
11 70
1500
F
PUD-240505
24
+5 +5 +100 +100 60
11 70
1500
F
PUD-241212
24
+12 +12 +41 +41 52
10 80
1500
F
Note: Other input to output voltages may be available. Please contact factory.
ORDERING INFORMATION:
FOR EXAMPLE: PUD-******(TWIN OUTPUT F PACKAGE)
9 NOMINAL INPUT VOLTAGE.
10 NOMINAL INPUT VOLTAGE, FULL LOAD.
DANUBE
http://www.danube.com.tw
5-4
2011/05/03




PUS-2405-3K.3 datasheet pdf
Download PDF
PUS-2405-3K.3 pdf
View PDF for Mobile


Similiar Datasheets : PUS-2405-3K.3

Index :   0   1   2   3   4   5   6   7   8   9   A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z   

This is a individually operated, non profit site. If this site is good enough to show, please introduce this site to others.
Since 2010   ::   HOME   ::   Privacy Policy + Contact