MLO110 Datasheet PDF - IXYS Corporation

www.Datasheet-PDF.com

MLO110
IXYS Corporation

Part Number MLO110
Description AC Controller Modules
Page 2 Pages


MLO110 datasheet pdf
View PDF for PC
MLO110 pdf
View PDF for Mobile


No Preview Available !

www.DataSheet4U.com
AC Controller Modules
MMO 110
MLO 110
IRMS = 112 A
VRRM = 800-1400 V
Preliminary Data
VRSM
VDSM
V
800
1200
1400
VRRM
VDRM
V
800
1200
1400
Type
MMO 110-08io7
MMO 110-12io7
MMO 110-14io7
MLO 110-08io7
MLO 110-12io7
MLO 110-14io7
MMO
(W1C)
I/H
A
G/F
N
MLO
(W1H)
A
I/H G/F
Symbol
IRMS
ITRMS
ITAVM
ITSM
I2t
(di/dt)cr
(dv/dt)cr
PGM
PGAVM
VRGM
TVJ
TVJM
Tstg
VISOL
Md
Weight
Conditions
Maximum Ratings
TC = 85°C, 50 - 400 Hz, module
TC = 85°C; (180° sine)
TVJ = 45°C
VR = 0
t = 10 ms (50 Hz), sine
t = 8.3 ms (60 Hz), sine
TVJ = 125°C
VR = 0
t = 10 ms (50 Hz), sine
t = 8.3 ms (60 Hz), sine
TVJ = 45°C
VR = 0
t = 10 ms (50 Hz), sine
t = 8.3 ms (60 Hz), sine
TVJ = 125°C
VR = 0
t = 10 ms (50 Hz), sine
t = 8.3 ms (60 Hz), sine
TVJ = 125°C
repetitive, IT = 50 A
f = 50 Hz, tP = 200 µs
VD = 2/3 VDRM
IG = 0.45 A
diG/dt = 0.45 A/µs
non repetitive, IT = ITAVM
TVJ = 125°C; VDR = 2/3 VDRM
RGK = ; method 1 (linear voltage rise)
TVJ = 125°C
IT = ITAVM
tp = 30 µs
tp = 300 µs
112
81
51
1000
1070
870
930
5000
4810
3780
3630
100
A
A
A
A
A
A
A
A2s
A2s
A2s
A2s
A/µs
500 A/µs
1000 V/µs
10 W
5W
0.5 W
10 V
-40...+150
150
-40...+125
°C
°C
°C
50/60 Hz, RMS
IISOL 1 mA
t = 1 min
t=1s
Mounting torque (M4)
2500
3000
V~
V~
1.5...2.0/14...18 Nm/lb.in.
typ. 18 g
Features
• Thyristor controller for AC (circuit
W1C acc. to IEC) for mains frequency
• Isolation voltage 3000 V~
• Planar glass passivated chips
• Low forward voltage drop
• Lead suitable for PC board solering
Applications
• Switching and control of single and
three phase AC circuits
• Light and temperature control
• Softstart AC motor controller
• Solid state switches
Advantages
• Easy to mount with two screws
• Space and weight savings
• Improved temperature and power
cycling
• High power density
• Small and light weight
Data according to IEC 60747 and to a single thyristor/diode unless otherwise stated.
IXYS reserves the right to change limits, test conditions and dimensions.
1-2
© 2002 IXYS All rights reserved



No Preview Available !

Symbol
ID , IR
VT
VT0
rT
VGT
IGT
VGD
IGD
IL
IH
tgd
RthJC
RthCH
dS
dA
a
Conditions
TVJ = 125°C; VR = VRRM; VD = VDRM
IT = 150 A; TVJ = 25°C
For power-loss calculations only
VD = 6 V
TVJ = 25°C
TVJ = -40°C
VD = 6 V
TVJ = 25°C
TVJ = -40°C
TVJ = 125°C; VD = 2/3 VDRM
TVJ = 25°C; tP = 10 µs
IG = 0.45 A; diG/dt = 0.45 A/µs
TVJ = 25°C; VD = 6 V; RGK =
TVJ = 25°C; VD = ½ VDRM
IG = 0.45 A; diG/dt = 0.45 A/µs
per thyristor; DC
per module
per thyristor; sine 180° el
per module
Creeping distance on surface
Creepage distance in air
Max. allowable acceleration
Dimensions in mm (1 mm = 0.0394")
MMO 110
MLO 110
Characteristic Values
5 mA
1.57
V
0.85 V
5.6 m
1.5 V
1.9 V
100 mA
200 mA
0.2 V
1 mA
200 mA
100 mA
2 µs
10
V
VG
1: IGT, TVJ = 125°C
2: IGT, TVJ = 25°C
3: IGT, TVJ = -40°C
3
1 2 56
1
4
IGD, TVJ = 125°C
0.1
100 101 102
4: PGAV = 0.5 W
5: PGM = 5 W
6: PGM = 10 W
103 mA 104
IG
Fig. 1 Gate trigger characteristics
0.8 K/W 1000
0.4 K/W
typ. 0.12 K/W µs
typ. 0.06 K/W
tgd
11.2 mm
17.0 mm
100
50 m/s2
TVJ = 25°C
typ. Limit
10
1
10 100
IG
Fig. 2 Gate trigger delay time
mA 1000
© 2002 IXYS All rights reserved
2-2



MLO110 datasheet pdf
Download PDF
MLO110 pdf
View PDF for Mobile


Related : Start with MLO11 Part Numbers by