HP2-AC200V Datasheet PDF - Panasonic

www.Datasheet-PDF.com

HP2-AC200V
Panasonic

Part Number HP2-AC200V
Description 10 AMP POWER RELAY
Page 13 Pages


HP2-AC200V datasheet pdf
View PDF for PC
HP2-AC200V pdf
View PDF for Mobile


No Preview Available !

www.DataSheet4U.com
Including discontinued products (
) HP
HP RELAYS10 AMP POWER RELAY
RoHS Directive compatibility information
http://www.mew.co.jp/ac/e/environment/
FEATURES
1. High-capacity and long life
Mechanical life is more than 10 million
operations and, with electrical life of more
than 200,000 operations (resistive load
10 A; inductive load 7.5 A), the relay has
excellent inductive load durability.
2. Easy mounting and wiring
The terminal arrangement is apparent at
a glance and wiring is easy. Moreover,
quick tab terminal is also possible.
3. Operation indicator option
Optional operation indicators are
available for easy visual confirmation that
relays are operating. They simplify
maintenance.
4. UL/CSA approved
5. Wide range of sockets and terminal
sockets
To enable use with DIN rails, DIN
terminal sockets are also available.
TYPICAL APPLICATIONS
HP relays enjoy wide use in various
applications, particularly in automation
controls and remote controls.
Applications include:
1. Industrial machinery
For controlling positioning, pressure, and
temperature in molding equipment,
boilers, pumps, charging pressure
equipment, measuring and evaluation
equipment, textile machines, etc.
2. Machine tools
Control of positioning and directional
change in turning machines, lathes,
borers, etc.
3. Food processing packing machines
Automatic control of packing equipment
for milk and seafood, bottling, canning,
and packaging
4. Office equipment
Control of copiers, time recorders, etc.
5. Coin operate machines
Control of food, cigarette, and other
vending machines
6. Transportation
Amplification of control signals in control
devices for vehicles and vessels,
functional parts of all kinds of equipment,
control signal repeating installation in
signaling devices and equipment.
7. Measuring devices and equipment
For repeating installation of control
signals and in power amplifiers
8. Generators, transformers and
power receiving equipment.
Functional parts in protective equipment,
functional assistance in automatic
adjustment equipment, telemeters and
other remote monitoring equipment
9. Control of conveyance equipment
Control panels for elevators, escalators,
and other conveyance equipment, control
of all kinds industrial transport equipment
such as conveyors.
10. Amusement equipment
Control of equipment in amusement
parks, etc., control of bowling alley
equipment, control of fountains in public
parks
About Cd-free contacts
We have introduced Cadmium free type
products to reduce Environmental
Hazardous Substances. (The suffix “F”
should be added to the part number. The
Suffix “F” is required only for 4 Form C
contact type. The 2 Form C and 3 Form C
contact type is originally cadmium-free,
the suffix “F” is not required.)
Please replace parts containing
Cadmium with Cadmium-free products
and evaluate them with your actual
application before use because the life of
a relay depends on the contact material
and load.
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.



No Preview Available !

HP
OwRwwD.DEatRaSIhNeeGt4U.IcNomFORMATION
HP
Contact arrangement
2: 2 Form C
3: 3 Form C
4: 4 Form C
Terminal arrangement
Nil: Standard plug-in terminal
TM: TM type (2 Form C only)
M: Direct mounting (3 Form C only)
Operation indication
Nil: Without indication
L: With indication
Coil voltage
AC 6, 12, 24, 48, 100, (115), 200, (220), (240) V
DC 6, 12, 24, 48, 100, (110) V
Contact material
F: 4 Form C, Silver alloy (cadmium-free)
Nil: 2 Form C, 3 Form C (Silver)
With LED indicator type
Coil voltage: 6, 12, 24 V AC 6, 12, 24, 48 V DC
With neon lamp type
Coil voltage: 100, 115, 200, 220, 240 V AC 100, 110 V DC
TYPES
1. Plug-in type
Coil voltage
2 Form C
Part No.
6V AC
HP2-AC6V
12V AC
HP2-AC12V
24V AC
HP2-AC24V
48V AC
HP2-AC48V
100V AC
HP2-AC100V
115V AC
HP2-AC115V
200V AC
HP2-AC200V
220V AC
HP2-AC220V
240V AC
HP2-AC240V
6V DC
HP2-DC6V
12V DC
HP2-DC12V
24V DC
HP2-DC24V
48V DC
HP2-DC48V
100V DC
HP2-DC100V
110V DC
HP2-DC110V
Standard packing (2 Form C): Carton: 20 pcs.; Case: 100 pcs.
Standard packing (3 Form C, 4 Form C): Carton: 10 pcs.; Case: 50 pcs.
Including discontinued products (
)
3 Form C
Part No.
HP3-AC6V
HP3-AC12V
HP3-AC24V
HP3-AC48V
HP3-AC100V
HP3-AC115V
HP3-AC200V
HP3-AC220V
HP3-AC240V
HP3-DC6V
HP3-DC12V
HP3-DC24V
HP3-DC48V
HP3-DC100V
HP3-DC110V
4 Form C
Part No.
HP4-AC6V-F
HP4-AC12V-F
HP4-AC24V-F
HP4-AC48V-F
HP4-AC100V-F
HP4-AC115V-F
HP4-AC200V-F
HP4-AC220V-F
HP4-AC240V-F
HP4-DC6V-F
HP4-DC12V-F
HP4-DC24V-F
HP4-DC48V-F
HP4-DC100V-F
HP4-DC110V-F
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.



No Preview Available !

Including discontinued products (
)
www.2D.aPtalSuhge-eint4tUy.pcoem(with LED indication)
Coil voltage
2 Form C
Part No.
6V AC
HP2-L-AC6V
With LED indication
12V AC
HP2-L-AC12V
24V AC
HP2-L-AC24V
100V AC
HP2-L-AC100V
115V AC
HP2-L-AC115V
With neon lamp
200V AC
HP2-L-AC200V
220V AC
HP2-L-AC220V
240V AC
HP2-L-AC240V
6V DC
HP2-L-DC6V
With LED indication
12V DC
24V DC
HP2-L-DC12V
HP2-L-DC24V
48V DC
HP2-L-DC48V
With neon lamp
100V DC
110V DC
HP2-L-DC100V
HP2-L-DC110V
Standard packing (2 Form C): Carton: 20 pcs.; Case: 100 pcs.
Standard packing (3 Form C, 4 Form C): Carton: 10 pcs.; Case: 50 pcs.
3 Form C
Part No.
HP3-L-AC6V
HP3-L-AC12V
HP3-L-AC24V
HP3-L-AC100V
HP3-L-AC115V
HP3-L-AC200V
HP3-L-AC220V
HP3-L-AC240V
HP3-L-DC6V
HP3-L-DC12V
HP3-L-DC24V
HP3-L-DC48V
HP3-L-DC100V
HP3-L-DC110V
HP
4 Form C
Part No.
HP4-L-AC6V-F
HP4-L-AC12V-F
HP4-L-AC24V-F
HP4-L-AC100V-F
HP4-L-AC115V-F
HP4-L-AC200V-F
HP4-L-AC220V-F
HP4-L-AC240V-F
HP4-L-DC6V-F
HP4-L-DC12V-F
HP4-L-DC24V-F
HP4-L-DC48V-F
HP4-L-DC100V-F
HP4-L-DC110V-F
3. TM type and Direct mount type
Coil voltage
6V AC
12V AC
24V AC
48V AC
100V AC
115V AC
200V AC
220V AC
240V AC
6V DC
12V DC
24V DC
48V DC
100V DC
110V DC
Standard packing: Carton: 10 pcs.; Case: 50 pcs.
2 Form C (TM type)
Part No.
HP2-TM-AC6V
HP2-TM-AC12V
HP2-TM-AC24V
HP2-TM-AC48V
HP2-TM-AC100V
HP2-TM-AC115V
HP2-TM-AC200V
HP2-TM-AC220V
HP2-TM-AC240V
HP2-TM-DC6V
HP2-TM-DC12V
HP2-TM-DC24V
HP2-TM-DC48V
HP2-TM-DC100V
HP2-TM-DC110V
3 Form C (direct mount type)
Part No.
HP3-M-AC6V
HP3-M-AC12V
HP3-M-AC24V
HP3-M-AC48V
HP3-M-AC100V
HP3-M-AC115V
HP3-M-AC200V
HP3-M-AC220V
HP3-M-AC240V
HP3-M-DC6V
HP3-M-DC12V
HP3-M-DC24V
HP3-M-DC48V
HP3-M-DC100V
HP3-M-DC110V
4. Direct mount type (with LED indication)
Coil voltage
3 Form C
Part No.
100V AC
HP3-ML-AC100V
115V AC
HP3-ML-AC115V
200V AC
HP3-ML-AC200V
With neon lamp
220V AC
HP3-ML-AC220V
240V AC
HP3-ML-AC240V
100V DC
HP3-ML-DC100V
110V DC
HP3-ML-DC110V
Standard packing: Carton: 10 pcs.; Case: 50 pcs.
Notes: 1. Standard packaging is handled in units of inner cartons. Please specify if you require inner cartons to be boxed.
2. Sockets, terminal sockets and installation brackets are not included. Please order these separately.
3. For products compliant with international standards, please refer to the standards chart.
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.



No Preview Available !

HP
Including discontinued products (
)
RwAwTw.IDNataGSheet4U.com
1. Coil data
1) AC coils
Contact
arrangement
Nominal coil
voltage
2 Form C
3 Form C
4 Form C
6V AC
12V AC
24V AC
48V AC
100V AC
115V AC
200V AC
220V AC
240V AC
6V AC
12V AC
24V AC
48V AC
100V AC
115V AC
200V AC
220V AC
240V AC
6V AC
12V AC
24V AC
48V AC
100V AC
115V AC
200V AC
220V AC
240V AC
Nominal coil current
(mA)
50Hz
60Hz
349mA 310mA
181.2mA 160mA
94mA
78mA
46.5mA
39mA
25.3mA
21mA
23.1mA
18mA
12.4mA
11mA
10.6mA 9.5mA
10.0mA 9.0mA
594mA 520mA
297mA 260mA
148.7mA 130mA
74.2mA
65mA
36.4mA
32mA
32.5mA 28.5mA
18.2mA
16mA
16.0mA 14.2mA
15.8mA 13.9mA
909mA 800mA
456mA 400mA
229mA 200mA
108mA
95mA
57.3mA
50mA
47.6mA
42mA
28.5mA
25mA
23.8mA
21mA
23.3mA 20.5mA
Nominal operating
power (VA)
50Hz
60Hz
2.09VA
1.9VA
2.17VA
1.9VA
2.25VA
1.9VA
2.23VA
1.9VA
2.36VA
2.1VA
2.31VA
2.1VA
2.48VA
2.2VA
2.34VA
2.1VA
2.40VA
2.2VA
3.56VA
3.1VA
3.56VA
3.1VA
3.56VA
3.1VA
3.56VA
3.1VA
3.64VA
3.2VA
3.74VA
3.3VA
3.65VA
3.2VA
3.54VA
3.1VA
3.79VA
3.3VA
5.46VA
4.8VA
5.47VA
4.8VA
5.49VA
4.8VA
5.18VA
4.6VA
5.73VA
5.0VA
5.47VA
4.8VA
5.69VA
5.0VA
5.24VA
4.6VA
5.58VA
4.9VA
Inductance
(H)
50Hz
60Hz
0.051
0.049
0.198
0.190
0.753
0.776
3.055
3.106
12.60
12.03
16.70
15.83
48.03
45.81
61.28
57.90
69.00
66.26
0.03
0.030
0.123
0.119
0.0494
0.475
1.976
1.899
8.500
8.038
10.79
10.36
33.53
32.10
41.35
39.32
45.94
44.05
0.020
0.019
0.080
0.077
0.320
0.309
1.348
1.292
5.348
5.156
7.264
6.953
21.27
20.45
27.75
26.57
30.98
29.75
Pick-up voltage Drop-out voltage
(at 20°C 68°F) (at 20°C 68°F)
Max. allowable
voltage
(at 20°C 68°F)
80%V or less of
nominal voltage
(Initial)
30%V or more of
nominal voltage
(Initial)
110%V of
nominal voltage
80%V or less of
nominal voltage
(Initial)
30%V or more of
nominal voltage
(Initial)
110%V of
nominal voltage
80%V or less of
nominal voltage
(Initial)
30%V or more of
nominal voltage
(Initial)
110%V of
nominal voltage
2) DC coils (20°C 68°F)
Contact
arrangement
2 Form C
3 Form C
4 Form C
Nominal coil
voltage
6V DC
12V DC
24V DC
48V DC
100V DC
110V DC
6V DC
12V DC
24V DC
48V DC
100V DC
110V DC
6V DC
12V DC
24V DC
48V DC
100V DC
110V DC
Nominal coil current
(mA)
240mA
109mA
54.5mA
26.7mA
14.9mA
15.0mA
250mA
120mA
60mA
31mA
15.6mA
14.9mA
273mA
127mA
63mA
32.0mA
16.3mA
15.7mA
Nominal operating
power (W)
1.5W
1.3W
1.3W
1.3W
1.5W
1.7W
1.5W
1.4W
1.4W
1.5W
1.6W
1.6W
1.6W
1.5W
1.5W
1.5W
1.6W
1.7W
Coil resistance
()
25
110
440
1,800
6,700
7,300
24
100
400
1,560
6,400
7,450
22
95
380
1,500
5,950
7,000
Pick-up voltage Drop-out voltage
(at 20°C 68°F) (at 20°C 68°F)
Max. allowable
voltage
(at 20°C 68°F)
80%V or less of
nominal voltage
(Initial)
15%V or more of
nominal voltage
(Initial)
110%V of
nominal voltage
80%V or less of
nominal voltage
(Initial)
15%V or more of
nominal voltage
(Initial)
110%V of
nominal voltage
80%V or less of
nominal voltage
(Initial)
15%V or more of
nominal voltage
(Initial)
110%V of
nominal voltage
Notes: 1. The rated current area is ±15% (60Hz) [AC coils],. ±10% (20°C) [DC coils]
2. The coil resistance for DC operation is the value measured when the coil temperature is 20°C 68°F. Compensate ±0.4% for every ±1°C change in temperature.
3. The relay operates in a range of 80% to 110% V of the voltage rating, but ideally, in consideration of temporary voltage fluctuations, it should be operated at the
rated voltage. In particular, for AC operation, if the impressed voltage drops to 80% V or more below the rated voltage, humming will occur and a large current will
flow leading possibly to coil burnout.
4. For use with 200 V DC, connect a 6.7k(10W) resistor, in series, to the 100 V DC relay [3 Form C type is .6.4k(5W); 4 Form C type is .6.2k(10W)].
5. As a general rule, only a pure DC voltage should be used for the coil drive.
However, a DC power supply that contains ripples has characteristics that differ from pure DC.
Therefore, please verify characteristics (operate voltage, release voltage, humming) using the actual circuit that will be used.
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.



HP2-AC200V datasheet pdf
Download PDF
HP2-AC200V pdf
View PDF for Mobile


Related : Start with HP2-AC200 Part Numbers by
HP2-AC200V 10 AMP POWER RELAY HP2-AC200V
Panasonic
HP2-AC200V pdf

Index :   0   1   2   3   4   5   6   7   8   9   A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z   

This is a individually operated, non profit site. If this site is good enough to show, please introduce this site to others.
Since 2010   ::   HOME   ::   Contact