Solid State Relay
G3S/G3SD
Ultra-small Relay Breaks up to 1 A
• Ultra-small, dual in-line package (DIP) SSR.
• Terminals compatible with G6B Electromagnetic Relay’s.
Mix with G6Bs as the application requires.
• Close side-by-side mounting possible. In addition, heat sink
dedicated to this mounting style also available.
• Both AC- and DC-load versions available.
• High isolation of 2,500 VAC between input and output free-
ing inputs from noise surge generated in the load.
• Approved by UL and CSA.
Ordering Information
To order: Select the part number and add the desired input voltage (Ex: G3SD-Z01P-PD-US DC12)
Isolation
Phototriac
Photocoupler
Zero cross function Indicator
No No
Rated output load Rated input voltage
(applicable output load)
Model
1 A at 100 to 240 VAC
(1 A at 75 to 264 VAC)
(see note 1)
5 VDC
12 VDC
24 VDC
G3S-201PL-US
1.2 A at 100 to 240 VAC
(1.2 A at 75 to 264 VAC)
(see note 1)
5 VDC
12 VDC
24 VDC
G3S-201PL-PD-US
1 A at 4 to 24 VDC
(1 A at 3 to 26 VDC)
(see note 2)
5 VDC
12 VDC
24 VDC
G3SD-Z01P-US
1.1 A at 4 to 24 VDC
(1.1 A at 3 to 26 VDC)
(see note 2)
5 VDC
12 VDC
24 VDC
G3SD-Z01P-PD-US
Note: 1. Product is labelled “250 VAC”
2. Product is labelled “24 VDC”
Accessories (Order Separately)
Heat Sink
Heat Sink
See Dimension for details.
Connecting Socket
Connecting socket
See Dimensions for details.
Y92B-S08N
P6D-04P
Solid State Relay G3S/G3SD
397
http://www.Datasheet4U.com



No Preview Available !

Specifications
Ratings (at an Ambient Temperature of 25°C)
Input
Rated voltage
Operating voltage
5VDC
12 VDC
24 VDC
4 to 6 VDC
9.6 to 14.4 VDC
19.2 to 28.8 VDC
Output
Model
G3S-201PL
G3S-201PL-PD
G3SD-Z01PL
G3SD-Z01PL-PD
Rated load voltage
100 to 240 VAC
4 to 24 VDC
Characteristics
Impedance
G3S-201PL/201PL-PD G3S-Z01PL/Z01P-PD
450 Ω±20%
630 Ω±20%
1.1 κΩ±20%
1.5 kΩ±20%
2.2 κΩ±20%
2.8 kΩ±20%
Voltage level
Must operate Must release
4 VDC max, 1 VDC min.
9.6 VDC max.
19.2 VDC max.
Applicable load
Rated load voltage range
Load current
75 to 264 VAC
0.1 to 1A
0.1 to 1.2 A
3 to 26 VDC
0.01 to 1A
0.01 to 1.1 A
Inrush current
15 A (60 Hz, 1 cycle)
3 A (10 ms)
Item
Operate time
Release time
Output ON voltage drop
Leakage current
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Ambient temperature
Ambient humidity
Approved standards
Weight
G3S-201PL/201PL-PD
G3SD-Z01PL/Z01P-PD
1 ms max.
1/2 of load power source cycle + 1 ms. max. 1 ms. max.
1.6 V (RMS) max.
1.5 V max.
2 mA max.
0.1 mA max. (at 26 VDC)
100 MΩ min. (500 VDC)
2,500 VAC, 50/60 Hz for 1 min
Malfunction: 10 to 55 Hz, 1.5-mm double amplitude
Malfunction: 1,000 m/s2
Operating: -30°C to 80°C (with no icing or condensation)
Storage: -30°C to 100°C (with no icing or condensation)
Operating: 45% to 85%
UL File No. E64562/CSA File No. LR35535
Approx. 13 g
398 Solid State Relay G3S/G3SD



No Preview Available !

Engineering Data
Load Current vs. Ambient
Temperature Characteristics
Inrush Current Resistivity
Non-repetitive (Keep the inrush current to half the rated value if it occurs repetitively.)
G3S-201PL-PD
G3SD-Z01P-PD
G3S-201PL
G3SD-Z01P
G3S-201PL
G3S-201PL-PD
G3SD-Z01P
G3SD-Z01P-PD
Ambient temperature (°C)
Energized time (ms)
Energized time (ms)
Dimensions
Note: All units are in millimeters unless otherwise indicated.
G3S/G3SD
20 max.
16.5 max.
16 max.
4
10.16 7.62
0.8
10 max.
PCB Dimensions
(Bottom View)
2.54 Four, 1.1 dia. holes
2.54
7.62±0.1
0.4
7.62
10.16±0.1 7.62±0.1
Terminal Arrangement/
Internal Connections
(Bottom View)
Input
voltage
+
()
1
Input
+
6
3 (+)
Load
4
Load
Note: Values in parentheses apply to the
DC-load versions.
()
Load power
supply
(+)
Solid State Relay G3S/G3SD 399



No Preview Available !

Connecting Socket
P6B-04P
10 max.
(9.9)*
(23)*
23.2 max.
3
PCB Dimensions
(Bottom View)
2.54
Four, 1.1-dia. holes
Heat Sink
Y92B-S08N
10.1 max.
(10)*
7
3.5
10.16 7.62
0.8
7.62 0.4
2.54
(2.71)
*Average value
48.2+00.3
1 8 1 6.3 1 6.3 1 6.3 1 6.3 1 8
1
20+00.3
8
+0
0.25
3
0.5
0.5
1
+0
0.2
Mounting Bracket
20+00.3
66
4 44
PCB Dimensions
(Bottom View)
7.62 4.5 7.62 4.5 7.62 4.5 7.62
16
4.2
0.7
2.6 0.8
7
15.5 18
10.16
7.62
Precautions
Close Mounting
G3S-201PL-PD and G3SD-Z 01-PD SS Rs can b e closely moun ted
side by side. Attach the Y92B-S08N Heat Sink to the SSRs mounted
closely side by side. When these SSRs are mounted side by side, the
load current vs. ambient temper ature char acteristic declines as
shown on the right.
Load Current vs. Ambient Temperature Characteristics
(When four SSRs are mounted side by side and each of
them is switched to the same load current.)
Ambient temperature (°C)
Connection
With the S SR for DC switching, the load can be connected to either
positive or negative output terminal of the SSR
Protective Component
Since the SSR does not incorporate an overvoltage absorption com-
ponent, be su re to connect an o vervoltage ab sorption compo nent
when using the SSR under an inductive load.
400 Solid State Relay G3S/G3SD



G3SD datasheet pdf
Download PDF
G3SD pdf
View PDF for Mobile


Related : Start with G3S Part Numbers by
G3S Ultra-small Relay Breaks up to 1 A G3S
OMRON
G3S pdf
G3SBA80 Glass Passivated Single-Phase Bridge Rectifier G3SBA80
General Semiconductor
G3SBA80 pdf
G3SD Ultra-small Relay Breaks up to 1 A G3SD
OMRON
G3SD pdf

Index :   0   1   2   3   4   5   6   7   8   9   A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z   

This is a individually operated, non profit site. If this site is good enough to show, please introduce this site to others.
Since 2010   ::   HOME   ::   Contact