E2K-X8MF2 Datasheet PDF - Omron

www.Datasheet-PDF.com

E2K-X8MF2
Omron

Part Number E2K-X8MF2
Description Cylindrical Proximity Sensor
Page 7 Pages


E2K-X8MF2 datasheet pdf
View PDF for PC
E2K-X8MF2 pdf
View PDF for Mobile


No Preview Available !

Cylindrical Proximity Sensor
E2K-X
General-purpose Threaded
Capacitive Sensor
• Product lineup with M12, M18, and M30 models.
• Fixed sensing distance requires no sensitivity adjustment.
CSM_E2K-X_DS_E_7_1
Be sure to read Safety Precautions on
page 5.
Ordering Information
Sensors [Refer to Dimensions on page 6.]
Appearance
Sensing distance
Unshielded
M12
M18
4 mm
8 mm
M30 15 mm
Accessories (Order Separately)
Mounting Brackets
Refer to Y92@ for details.
Output configuration
DC 3-wire, NPN
DC 3-wire, PNP
AC 2-wire
DC 3-wire, NPN
DC 3-wire, PNP
AC 2-wire
DC 3-wire, NPN
DC 3-wire, PNP
AC 2-wire
Model
Operation mode
NO NC
E2K-X4ME1 2M
E2K-X4ME2 2M
E2K-X4MF1 2M
E2K-X4MF2 2M
E2K-X4MY1 2M
E2K-X4MY2 2M
E2K-X8ME1 2M
E2K-X8ME2 2M
E2K-X8MF1 2M
E2K-X8MF2 2M
E2K-X8MY1 2M
E2K-X8MY2 2M
E2K-X15ME1 2M
E2K-X15ME2 2M
E2K-X15MF1 2M
E2K-X15MF2 2M
E2K-X15MY1 2M
E2K-X15MY2 2M
1



No Preview Available !

Ratings and Specifications
E2K-X
Item
Model
E2K-X4ME@,
E2K-X4MF@,
E2K-X4MY@
E2K-X8ME@,
E2K-X8MF@,
E2K-X8MY@
E2K-X15ME@,
E2K-X15MF@,
E2K-X15MY@
Sensing distance
4mm ±10%
8 mm ±10%
15 mm ±10%
Set distance *1
0 to 2.8 mm
0 to 5.6 mm
0 to 10 mm
Differential travel
4% to 20% of sensing distance
Detectable object
Conductors and dielectrics
Standard sensing object Grounded metal plate: 50 × 50 × 1 mm
Response frequency
E and F Models: 100 Hz, Y Models: 10 Hz
Power supply voltage*2 E and F Models: 12 to 24 VDC (10 to 30 VDC)
(operating voltage range) Y Models: 100 to 220 VAC (90 to 250 VAC)
Current consumption
E and F Models: 15 mA max.
Leakage current
Y Models: 2.2 mA max. (Refer to page 4.)
Load current E and F Models: 200 mA max.*2, Y Models: 10 to 200 mA
Control
output
Residual voltage
E and F Models: 2 V max. (Load current: 200 mA, Cable length: 2 m), Y Models: Refer to Engineering Data on
page 4.
Indicators
E and F Models: Detection indicator (red), Y Models: Operation indicator (red)
Operation mode
(with sensing object
approaching)
E1, F1, and Y1 Models: NO
E2, F2, and Y2 Models: NC
Refer to the timing charts under I/O Circuit Diagrams on page 4 for details.
Protection circuits
E and F Models: Reverse polarity protection, Surge suppressor, load short-circuit protection, output reverse polar-
ity protection, Y Models: Surge suppressor
Ambient temperature
range
Operating/Storage: 25 to 70°C (with no icing or condensation)
Operating/Storage: 10 to 55°C
(with no icing or condensation)
Ambient humidity range Operating/Storage: 35% to 95% (with no condensation)
Temperature influence
±20% max. of sensing distance at 23°C in the operating temperature range
Voltage influence
E and F Models: ±2% max. of sensing distance at rated voltage at rated voltage ±20%
Y Models: ±2% max. of sensing distance at rated voltage at rated voltage ±10%
Insulation resistance
50 MΩ min. (at 500 VDC) between current-carrying parts and case
Dielectric strength
E and F Models: 1,000 VAC, 50/60 Hz for 1 min between current-carrying parts and case
Y Models: 2,000 VAC, 50/60 Hz for 1 min between current-carrying parts and case
Vibration resistance
Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance
Destruction: 500 m/s2 3 times each in X, Y, and Z directions
Degree of protection
IP66 (IEC), in-house standards: oil-resistant
Connection method
Pre-wired Models (Standard cable length: 2 m)
Weight (packed state)
Approx. 65 g
Approx. 145 g
Approx. 205 g
Materi-
als
Case
Heat-resistant ABS
Sensing surface
Clamping nuts Polyacetal
Accessories
Instruction manual
*1. The above values are sensing distances for the standard sensing object. Refer to Engineering Data on page 3 for other materials.
*2. E and F Models (DC switching models): A full-wave rectification power supply of 24 VDC ±20% (average value) can be used.
2



No Preview Available !

Engineering Data (Reference Value)
Sensing Area (Grounded Metal Plate)
E2K-X4M
18
16
14
Y
12 X
Standard sensing
10 object Grounded
metal plate
50 × 50 × 1 mm
8
6
E2K-X15M
E2K-X8M
4
E2K-X4M
2
0
5 20 15
10 5 0 5 10
E2K-X4M Sensing
E2K-X8M Sensing Head
E2K-X15M Sensing Head
15 20 25
Distance
Y (mm)
Influence of Sensing Object Size and Material
E2K-X4M
E2K-X8M
5 d×
d t = 3 mm
X
4
Grounded metal
10 d ×
d t = 3 mm
X
8
Grounded metal
36
Non-grounded metal
Non-grounded metal
24
1
Glass
Phenol
0 10 20 30 40 50 60 70
Side length of sensing object: d (mm)
Glass
2
Phenol
Acryl
0 10 20 30 40 50 60 70
Side length of sensing object: d (mm)
Sensing Object Thickness and Material vs. Sensing Distance
E2K-X4M
E2K-X8M
5 10
4
50 ×
50 t
X
3
2
1
Grounded metal
Non-grounded metal
Glass
Phenol
0 5 10 15 20 25
Thickness of sensing object: t (mm)
8
50 ×
50 t
X
6
4
2
Grounded metal
Non-grounded metal
Glass
Phenol
Acryl
0 5 10 15 20 25
Thickness of sensing object: t (mm)
E2K-X
E2K-X15M
25 d ×
d t = 3 mm
X
20
15 Grounded metal
Non-grounded metal
10
Glass
Phenol
5 Acryl
0 10 20 30 40 50 60 70
Side length of sensing object: d (mm)
E2K-X15M
25
50 ×
50 t
X
20
15
10
5
Grounded metal
Non-grounded metal
Glass
Phenol
Acryl
0 5 10 15 20 25
Thickness of sensing object: t (mm)
3



No Preview Available !

E2K-X
Leakage Current
E2K-X@MY
2.0
1.5
Protective resistance
(OFF)
mA
V
AC
power,
50/60Hz
1.0
Residual Output Voltage
E2K-X@MY@
at 100 VAC
120
Residual output voltage
100
ON
80
V
60
VL
40
100 VAC
A
E2K-X@MY@
240
Residual output voltage
200
at 200 VAC
ON
160
V
120
VL
200 VAC
80 A
20
Residual
0 Load Voltage
0 100 200 300 3 5 10
Power supply voltage (V)
I/O Circuit Diagrams
DC 3-Wire Models (NPN)
Operation
mode
Model
E2K-X4ME1
NO E2K-X8ME1
E2K-X15ME1
E2K-X4ME2
NC E2K-X8ME2
E2K-X15ME2
DC 3-Wire Models (PNP)
Operation
mode
Model
E2K-X4MF1
NO E2K-X8MF1
E2K-X15MF1
E2K-X4MF2
NC E2K-X8MF2
E2K-X15MF2
AC 2-Wire Models
Operation
mode
Model
E2K-X4MY1
NO E2K-X8MY1
E2K-X15MY1
E2K-X4MY2
NC E2K-X8MY2
E2K-X15MY2
Timing chart
Sensing object
Load (between brown
and black leads)
Present
Not present
Operate
Reset
Output voltage (between
black and blue leads)
High
Low
Detection indicator (red)
ON
OFF
Sensing object
Present
Load (between brown
and black leads)
Not present
Operate
Reset
Output voltage (between
black and blue leads)
High
Low
Detection indicator (red)
ON
OFF
Timing chart
Sensing
object
Present
Not present
Load (between blue
and black leads)
Operate
Reset
Output voltage (between High
black and brown leads) Low
Detection
indicator (red)
ON
OFF
Sensing
object
Present
Not present
Load (between blue
and black leads)
Operate
Reset
Output voltage (between High
black and brown leads) Low
Detection
indicator (red)
ON
OFF
Timing chart
Sensing object
Present
Not present
Load
Operate
Reset
Operation indicator (red) ON
OFF
Sensing object
Present
Not present
Load
Operate
Reset
Operation indicator (red) ON
OFF
20 30
OFF
50 100 200
Load current (mA)
40 Residual
Load
Voltage
0
35
10
20 30
OFF
50 100 200
Load current (mA)
Output circuit
Brown
+V
Proximity
Sensor
main
circuit
10 kΩ
*1 Load
Black
*2
Tr
Blue
*1. Load current: 200 mA max.
*2. When a transistor is connected.
0V
Output circuit
Brown
+V
Proximity
Sensor
main
circuit
2.2 Ω
3.9 kΩ 47 kΩ
*2
Black*1
Load
Blue
*1. Load current: 200 mA max.
*2. When a transistor is connected.
0V
Output circuit
Proximity
Sensor
main
circuit
Brown
Load
Blue
4



E2K-X8MF2 datasheet pdf
Download PDF
E2K-X8MF2 pdf
View PDF for Mobile


Related : Start with E2K-X8MF Part Numbers by
E2K-X8MF1 Cylindrical Proximity Sensor E2K-X8MF1
Omron
E2K-X8MF1 pdf
E2K-X8MF2 Cylindrical Proximity Sensor E2K-X8MF2
Omron
E2K-X8MF2 pdf

Index :   0   1   2   3   4   5   6   7   8   9   A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z   

This is a individually operated, non profit site. If this site is good enough to show, please introduce this site to others.
Since 2010   ::   HOME   ::   Privacy Policy + Contact