20-JS6DT4 Datasheet PDF - MTU Onsite Energy

www.Datasheet-PDF.com

20-JS6DT4
MTU Onsite Energy

Part Number 20-JS6DT4
Description DIESEL ENGINE-GENERATOR SET
Page 4 Pages


20-JS6DT4 datasheet pdf
View PDF for PC
20-JS6DT4 pdf
View PDF for Mobile


No Preview Available !

A tognum Group Brand
Diesel Engine-Generator Set
20-JS6DT4
20 ekW / 60 Hz / Standby
208 - 600V
System Ratings
Standby
Voltage (L-L)
Phase
PF
Hz
kW
kVA
AMPS
skVA@30%
Voltage Dip
Generator Model
Temp Rise
Connection
** UL2200 Offered
240V**
1
1.0
60
20
20
83
35
283CSL1506
130°C/27°C
12 LEAD ZIG-ZAG
208V**
3
0.8
60
20
25
69
52
283CSL1506
130°C/27°C
12 LEAD LOW WYE
240V**
3
0.8
60
20
25
60
52
283CSL1506
130°C/27°C
12 LEAD HI DELTA
480V**
3
0.8
60
20
25
30
75
283CSL1506
130°C/27°C
12 LEAD HI WYE
600V**
3
0.8
60
20
25
24
123
284PSL1752
125°C/40°C
4 LEAD WYE
Facts
//  EPA Tier 4 Certified
//  Engine-Generator Set Tested to ISO 8528-5 for
Transient Response
//  UL2200, CSA Listing Offered
//  Accepts Rated Load in One Step Per NFPA 110, Level 1
//  All engine-generator sets are prototype and factory tested
ww/w/  .DMaTtUaSOhneseitt4eUE.cnoemrgy is a single source supplier
//  Global Product Support
//  2 Year Standard Warranty
//  4024TF281 Diesel Engine
- 2.4 Liter Displacement
- 4-Cycle
//  Complete Range of Accessories
//  Permanent Magnet Generator (PMG) - Optional
- Brushless, Rotating Field
- 300% Short Circuit Capability
- 2/3 Pitch Windings
//  Digital Control Panel(s)
- UL Recognized, , NFPA 110
- Complete System Metering
- LCD Display
//  Cooling System
- Integral Set-Mounted
- Engine Driven Fan



No Preview Available !

2 / //  / 20-JS6DT4
STANDARD EQUIPMENT
//  Engine
Air Cleaner
Oil Pump
Full Flow Oil Filter
Jacket Water Pump
Closed Crankcase Vent
Thermostats
Exhaust Manifold – Dry
Blower Fan & Fan Drive
Radiator - Unit Mounted
Electric Starting Motor - 12V
Governor – Electric Isochronous
Base - Formed Steel
SAE Flywheel & Bell Housing
Charging Alternator - 12V
Battery Box & Cables
Flexible Fuel Connectors
Flexible Exhaust Connection
EPA Certified Engine
//  Generator
NEMA MG1, IEEE and ANSI standards compliance for temperature rise
and motor starting
Sustained short circuit current of up to 300% of the rated current for up
to 10 seconds
Self-Ventilated and Drip-Proof
Superior Voltage Waveform
Digital, Solid State, Volts-per-Hertz Regulator
No Load to Full Load Regulation
Brushless Alternator with Brushless Pilot Exciter
4 Pole, Rotating Field
130°C Standby Temperature Rise
1 Bearing, Sealed
Flexible Coupling
Full Amortisseur Windings
125% Rotor Balancing
3-Phase Voltage Sensing
±1% Voltage Regulation
100% of Rated Load - One Step
3w% wMwax.iDmaumtaSHhaermeto4nUic.cCoomntent
//  Digital Control Panel(s)
Digital Metering
Engine Parameters
Generator Protection Functions
Engine Protection
SAE J1939 Engine ECU Communications
Windows-Based Software
Multilingual Capability
Remote Communications to our RDP-110 Remote Annunciator
16 Programmable Contact Inputs
7 Contact Outputs
UL Recognized,
, CE Approved
Event Recording
IP 54 Front Panel Rating with Integrated Gasket
NFPA110 Level Compatible
//  Additional Features
Oil Drain Extension & S/O Valve
Flexible Fuel Connector
Battery Cables
Vibration Isolation Pads
Jacket Water Heater: -20° F
Mainline Circuit Breaker
UL2200 Listed
Steel Sub-Base
Radiator Duct Flange (OPU)
Lube Oil & Antifreeze
Operator’s and Owner’s Manual
2 Year/3000 Hour Warranty
Factory Tested at 0.8 PF (3 PH)
//  Optional Features
Battery Charger: 6 Amp or 10 Amp
Battery: 12 Volt w/ Rack
Circuit Breaker: Standard or 100%
Muffler (OPU only)
Sub-Base Fuel Tank w/ Electrical Stub-Up Area
Weatherproof Enclosure
Sound Attenuation
- 1 1/2” Foam
- Sound Scoops
Remote Annunciator
Isochronous Governor



No Preview Available !

3 / //  / 20-JS6DT4
Application data
//  Engine
Manufacturer
Model
Type
Arrangement
Displacement: Cu In (lit)
Bore: in (cm)
Stroke: in (cm)
Compression Ratio
Rated RPM
Engine Governor
Max Power: Standby: bhp (kWm)
Regulation
Frequency
Air Cleaner
//  Liquid Capacity (Lubrication)
Total Oil System: gal (lit)
Engine Jacket Water Capacity: gal (lit)
System Coolant Capacity: gal (lit)
//  Electrical
Electric Volts DC
Cold Cranking Amps Under 0°F (-17.8°C)
//  Fuel System
Fuel Supply Connection Size
Fuel Return Connection Size
Maximum Fuel Lift: ft (m)
Recommended Fuel
Total Fuel Flow: gal/hr (lit/hr)
John Deere
4024TF281
4-Cycle
4-Inline
149 (2.4)
3.4 (8.6)
4.1 (10.5)
20.5:1
1,800
Electric Isochronous
49 (36)
±1%
60 Hz
Dry
2.1 (8)
0.675 (2.6)
2.29 (8.7)
12
750
3/8” NPT
3/8” NPT
10 (3)
Diesel #2
26.4 (100)
//  Fuel Consumption
At 100% of Power Rating: gal/hr (lit/hr)
At 75% of Power Rating: gal/hr( lit/hr)
At 50% of Power Rating: gal/hr (lit/hr)
//  Cooling - Radiator System
Ambient Capacity of Radiator: °F (°C)
Max. Restriction of Cooling Air, Intake,
and Discharge Side of Rad.: in. H20 (kPa)
Water Pump Capacity: gpm (lit/min)
Heat Rejection to Coolant: BTUM (kW)
Heat Radiated to Ambient: BTUM (kW)
//  Air Requirements
Aspirating: *SCFM (m3/min)
Air Flow Required for Rad.
Cooled Unit: *SCFM (m3/min)
Air Flow Required for Heat
Exchanger/Remote Rad. based
on 25°F Rise: *SCFM (m3/min)
* Air density = 0.0739 lbm/ft3 (1.184 kg/m3)
//  Exhaust System
Gas Temp. (Stack): °F (°C)
Gas Volume at Stack
Temp: CFM (m3/min)
Maximum Allowable
Back Pressure: in. H20 (kPa)
1.9 (7.2)
1.4 (5.3)
1 (3.8)
122 (50)
0.5 (0.12)
24 (91)
1,412 (25)
376 (7)
106 (3)
2,645 (75)
650 (18.4)
1,026 (552)
283 (8)
30 (7.5)
www.DataSheet4U.com



No Preview Available !

Weights and dimensions
4 / //  / 20-JS6DT4
Drawing above for illustration purposes only, based on standard open power 480 volt generator. Lengths may vary with other voltages. Do not use for installation design.
System Dimensions (L x W x H)
OPU
70 x 34 x 52 in (1,780 x 860 x 1,320 mm)
EPU 70 x 34 x 59 in (1,780 x 860 x 1,500 mm)
Height w/Tank 24hr.
76 in (1,930 mm)
83 in (2,110 mm)
Weight (less tank)
1,684 lb (764 kg)
2,338 lb (1,060 kg)
Weights and dimensions are based on open power units and are estimates only. Consult the factory for accurate weights and dimensions for your specific generator set.
Sound data
Unit Type
OPU w/ Critical Grade Muffler (dBA)
Sound Attenuated Enclosure (dBA)
Measurements for sound data are taken at 23 ft (7 m).
Emissions data
Standby Full Load
83
76
Standby No Load
74
66
Rating Definitions and conditions
NOx + NMHC
C/F
CO PM
C/F C/F
All units are in g/hp-hr and are EPA D2 cycle values.
Emission levels of the engine may vary as a function of ambi-
ent temperature, barometric pressure, humidity, fuel type and
quality, installation parameters, measuring instrumentation,
etc. The data provided are laboratory results from one engine
representing this rating. The data was obtained under cont-
rolled environmental conditions with calibrated instrumentation
traceable to the United States National Bureau of Standards
and in compliance with US EPA regulations found within 40 CFR
Part 89. The weighted cycle value from each engine is guaran-
teed to be below the US EPA Standards at the US EPA defined
conditions.
www.DataSheet4U.com
//  Ambient capability factor at 984 ft (300 m). Consult your
local MTU Onsite Energy Power Generation Distributor for
other altitudes.
//  Standby ratings apply to installations served by a reliable
utility source. The standby rating is applicable to varying
loads for the duration of a power outage. No overload capa-
bility for this rating. Ratings are in accordance with
ISO-3046/1, BS 5514, AS 2789, and DIN 6271.
//  Deration Factor:
Altitude: 0.5% per 1,000 ft (305 m) above 5,000 ft
(1,524 m) and 4% per 1,000 ft (305 m) above 7,000 ft
(2,286 m).
Temperature: 0.5% per 10°F (5.5°C) above 77°F (25°C).
Materials and specifications subject to change without notice.
// Tognum Group Companies: Europe / Middle East / Africa / Latin America / MTU Onsite Energy / 88040 Friedrichshafen / Germany / Phone + 49 7541 90 7060 /
Fax +49 7541 90 7084 / powergenregion1@mtu-online.com // Asia / Australia / Pacific / MTU Onsite Energy / 1, Benoi Place / Singapore 629923 / Republic of Singapore /
Phone + 65 6861 5922 / Fax + 65 6861 3615 / powergenregion2@mtu-online.com // USA / Canada / Mexico / MTU Onsite Energy / 100 Power Drive / Mankato, Minnesota
56001 / USA / Phone + 1 507 625 7973 / Fax + 1 507 625 2968 / powergenregion3@mtu-online.com // Worldwide for HotModule / MTU Onsite Energy / 81663 Munich /
Germany / Phone + 49 89 203042 800 / Fax +49 89 203042 900 / info@mtu-online.com // www.mtu-online.com



20-JS6DT4 datasheet pdf
Download PDF
20-JS6DT4 pdf
View PDF for Mobile


Related : Start with 20-JS6DT Part Numbers by
20-JS6DT4 DIESEL ENGINE-GENERATOR SET 20-JS6DT4
MTU Onsite Energy
20-JS6DT4 pdf

Index :   0   1   2   3   4   5   6   7   8   9   A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   X   Y   Z   

This is a individually operated, non profit site. If this site is good enough to show, please introduce this site to others.
Since 2010   ::   HOME   ::   Contact